Our Products & Services

Hensotherm 471KS

Product Descriptions

Superior protection for structural steels used in construction of commercial and residential buildings, hospitals, schools, food and beverage processing plants, clean rooms, cold rooms, mechanised car parks, bus and train stations, infrastructures and more.

Performance & Compliance 

It can provide up to 03 hours or R180 of fire resistant when applied to applicable steel types and sizes. It is tested to British Standards BS476 Part 20/21 and BS8202 Part 2. 

Applicable Critical Temperature

BS476 Part 20/21 with BS8202 Part 2 detailed in COC 

550°C 4-sided expose column and 620°C for 3-sided expose horizontal beams

EN 13381-8 and EN 16623 

500°C for both columns and beams .Hensotherm 471KS is also known as Hensotherm 421KS, certified and complies with EURO Standards EN 13381-8 and EN 13501-2 detailed in ETA 16/0251. 

In Singapore, Hensotherm 471KS obtained its local Certificate of Conformity complying to BS476 Part 20/21 with BS 8202 Part 2

Hensotherm 820KS

Product Description

Besides steel structure, concrete too can be, and they should be PROTECTED as well. Hensotherm 820KS is commonly use as sacrificial layer that can prevent overheating of the concrete rebars, that could results in the following:

  • Rapid flame spreading
  • Rapid thermal migration
  • Rapid expansion
  • Cracking
  • Spalling
  • Reaching critical temperature prematurely 

Performance and Compliance Patented Product – European Patent No. 2686391 EWCL Certification (ME 5119)  Area of Application

  • Concrete hollow core slabs
  • Flat concrete ceiling, beam, column and wall
  • Ribbed ceiling 

Often overlooked, but such protections are gaining more acceptance as building owners, consultants and engineers pay more attention to preventing unforeseen fire hazard.   

Firecut F1

Product Descriptions

Traditional and long established cement and vermiculite mixture fireproofing spray (SFRM) for protection of usually non-exposed to view structural steel used for construction of residential, commercial and infrastructure facilities. It is usually used for protection of basement or elevated structures that require fire resistance withstanding at least 4 hours or R240. 

Performance & Compliance 

It can provide up to 05 hours or R300 of fire resistant when applied to applicable steel types and sizes. It is tested to British Standards BS476 Part 20/21 and BS476 Part 4. 

UL263 and ASTM 423 UL GREENGUARD Certification

Medium density product with excellent resistance against abrasion, impact, air erosion, etc.

Suitable for indoor use

Suitable for outdoor use with top sealer applied

Applicable Critical Temperature

BS476 Part 20/21 with BS476 Part 4 detailed in COC  550°C 4-sided expose column and  620°C for 3-sided expose horizontal beams

In Singapore, Firecut F1 obtain a local Certificate of Conformity complying to  BS476 Part 20/21 & BS476 Part 4
 

Firecut F100

Product Descriptions

Traditional and long established cement and vermiculite mixture fireproofing spray (SFRM) for protection of usually non-exposed to view structural steel used for construction of residential, commercial and infrastructure facilities. It is also used in Oil and Gas industries where high temperature exposure is expected. It is suitable for protection of basement or elevated structures that require fire resistance withstanding at least 4 hours or R240.

Performance & Compliance

It can provide up to 05 hours or R300 of fire resistant when applied to applicable steel types and sizes. It is tested to British Standards BS476 Part 20/21 and BS476 Part 4. It is certified to UL1709, suitable for hydrocarbon fire protection (Oil & Gas Industries use) High density product with excellent resistance against abrasion, impact, air erosion, etc. Suitable for indoor use Suitable for outdoor use (with or without top sealer)

Applicable Critical Temperature BS476 Part 20/21 and BS476 Part 4 detailed in COC 550°C 4-sided expose column and 620°C for 3-sided expose horizontal beams UL 1790 Design no XR 713 UL 263 ASTM 423 UL GREENGUARD Certification

Core Services

Core services;

Fireproofer service: For new build or renovation project

  • Structural steel 
  • Timber and solid wood 
  • M&E 
  • Concrete enhancement
  • Firestopping

Secondary Services

Sound and thermal insulation: For new build or renovation project

  • Treating and improving the insulation to building experiencing condensation occurring on exterior wall, room, ceiling and even floors.
  • Sound shielding against unwanted echo and migration of sound in both private and public enclosures.